<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-05 05-20-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.50 MHz 5/5, 51 dBuV ISKELMA
Pilot RDS Phase Difference
4.3 kHz 1.4 kHz -1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
18 kHz 43 kHz 10586 0,3873
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 1,82 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 0 0 --:--
RT
-
AF EON
89.4, 92.5, 100.1, 107.7 MHz -
FM Scope Max at: 43 kHz MIN: 18 kHz % above 76 kHz: 0,3873 Acquired: 2025/01/05 5.19.20 Total samples: 10586 Equivalent time: 0:08:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500